Logistics warehouse: preparing the lighting for peak activity
The end-of-year peak extends working hours and brings into the building teams who know neither its aisles nor its routines. Here are the interventions that can be carried out without stopping operations, and what instead belongs in a renovation plan after the season.
5 min read

At the end of October, the warehouse moves to two shifts, then three. Temporary staff arrive, discover the aisles at night and look for references they have never handled. The lighting that was enough for a day team used to the premises then becomes the leading cause of picking errors.
What night work changes in lighting needs
At night, the contribution of natural light disappears completely. Buildings fitted with rooflights or translucent strips lose a share of illuminance that does not appear in any survey carried out during the day. The areas close to the façades are the first to be affected.
Alertness also drops. For the same task, a good illuminance level and good uniformity matter more at night than during the day. Reading an alphanumeric code on a rack label is a demanding visual task, which deteriorates quickly at the end of a shift.
Finally, the staff change: reinforced teams, temporary workers, staggered hours. Operators who do not know the building do not compensate for lighting defects out of habit, unlike permanent teams who know where to slow down.
Picking areas and reading labels
Picking depends on vertical illuminance, not on illuminance at floor level. The label is vertical, so is the face of the pallet, and the operator stands between the luminaire and the target, and therefore in their own shadow.
The EN 12464-1 standard requires 150 lux in storage aisles where personnel move about, and only 50 lux in aisles with no permanent presence. These values are safety minimums, not performance levels for a fast, repetitive reading task.
- Identify the aisles where the operator always works against the light.
- Check the legibility of labels at the lowest and highest level of each rack.
- Check recently rearranged aisles, where the lighting layout has not followed the new storage plan.
- Report the aisles where tall pallets cast a permanent shadow on the neighbouring face.
Luminaires dedicated to storage and logistics offer elongated distributions designed for these aisles, to be preferred in intensive picking areas.
Packing areas and quality control stations
The standard sets packing and dispatch areas at 300 lux. Control and inspection stations require more, with a colour rendering of at least Ra 80: spotting a damaged product, a wrong label or a difference in colour requires faithful light.
These stations are fixed, which simplifies the intervention. A well-placed local supplement deals with the problem without touching the general lighting of the building. Orientation matters as much as level, so that the operator does not work in their own shadow or facing a reflection on stretched plastic film.
Circulation and forklift-pedestrian crossings
The crossing points between vehicles and pedestrians concentrate the risk. Blind spots at the end of aisles, exits from charging areas and crossings of preparation areas deserve specific treatment, separate from the general lighting.
The French Labour Code sets a minimum of 40 lux for internal traffic routes and 120 lux for premises used for work. At a crossing, the useful criterion remains contrast: a person must stand out from the background before the vehicle reaches them.
Recent floor markings do not replace light. Painted in a dark area, they become invisible as soon as the approaching forklift casts its own shadow.
Quick interventions possible without stopping operations
Before the ramp-up, several actions can be carried out during off-peak hours, without immobilising an entire area or blocking an aisle for a whole day.
- Clean the diffusers and optics of the accessible luminaires, as dirt reduces the useful flux.
- Replace faulty or flickering luminaires, identified during a night round.
- Readjust the detection and time-delay settings in little-used aisles.
- Add a local supplement on the fixed packing and control stations.
- Rebalance the circuits so that all the aisles open for picking are actually powered.
Linear battens installed surface-mounted or suspended above a fixed station go up quickly and do not disrupt operations in the neighbouring aisles.
Spotting end-of-life luminaires before the ramp-up
An LED luminaire does not go out all at once. It gradually loses flux, sometimes drifts in shade, and its power supply components often fail before the diodes. The signs can be spotted by eye during a simple round.
- A luminaire noticeably yellower or darker than its neighbours of the same reference.
- Visible flicker, often perceived first in peripheral vision.
- Slow or irregular start-up, a sign of a power supply at the end of its life.
- A yellowed, cracked or pitted diffuser, which absorbs part of the flux emitted.
This round is done by two people, at night, with the building plan and a marker. It takes one evening and avoids breakdowns in the middle of the season, at the very moment when no intervention is possible without disrupting production.
What belongs in a renovation plan after the season
Not everything is dealt with as an emergency. A layout unsuited to the current racks, an inconsistent mounting height or an entire stock of luminaires at the end of its life call for a project, not a quick fix on the eve of the peak.
The peak period is, however, the best time to observe and take notes. It is the only time of the year when the building runs at full load, at night, with operators who are not used to it: defects that go unnoticed the rest of the time become obvious.
These observations feed directly into the specifications. An audit of the building's lighting turns them into a costed programme, and the comparable projects already completed give benchmarks on how works proceed in an occupied site.
Schedule the inspection round this week and have the list of luminaires to be replaced validated by the operations manager.
Find the right equipment in the industrial warehouses category.
Further reading: Car park lighting: height, layout and uniformity and Office lighting: LED panel or linear pendant. Reference: NF EN 12464-1 standard on indoor workplace lighting (AFNOR).
In the Rexylum catalogue: REXLINELIGHT · Continuous Line System and STARLOG 31 · High-Ceiling Floodlight. To size the installation: a photometric study by a lighting design office.