Detailed description
The FLAT LINE/GAMMA is a linear luminaire designed for areas where standard lighting electronics degrade quickly: rooms exposed to ionising radiation. It is certified to withstand a cumulative dose of 150 kGy of Gamma radiation, a constraint that puts an ordinary commercial fitting out of service in a short time. It is intended for operators of nuclear facilities, specialised engineering firms and integrators who must qualify every piece of equipment in a controlled area.
Applications
- Reactor buildings and peripheral rooms of nuclear facilities.
- Areas for processing, packaging and storing radioactive materials.
- Irradiation cells and applied research laboratories.
- Technical galleries and service rooms exposed to both radiation and humidity.
Technical highlights
- Withstands 150 kGy Gamma: the admissible cumulative dose determines how long the luminaire remains usable in its area. It is the number one selection criterion, even before flux.
- Seismic resistance IEC 60980: the fitting is qualified to stay in place and keep working during a seismic event, which matters for lighting escape routes and classified rooms.
- Range from 10 to 60 W, nominal 40 W version for 6,400 lm: i.e. 160 lm/W, an efficacy that limits the number of light points to install in rooms where every maintenance intervention is costly to organise.
- IP65: dust-tight and protected against water jets, therefore compatible with washing-based decontamination protocols.
- IK07: mechanical resistance to the impacts common during handling in technical rooms.
- 70,000 h service life: spacing out replacements is decisive when access to the area is regulated and timed.
- Weight from 1.6 to 4.5 kg depending on the version: to be included in the calculation of supports and fixings.
Choose this model if your specification requires a documented cumulative Gamma dose and seismic resistance: it is this pair of requirements that sets it apart from a conventional IP65 industrial linear luminaire. The choice of power in the 10 to 60 W range and the layout are then calculated from the ceiling height and the target illuminance levels room by room.